Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

For Dissolution test why we are Performing 6 Bowls why not
more.any were mentioned or in what basis we are performing?

--------Veerabhadrarao.M

Answer Posted / deepankar gupta

Higher confidence level in multiples of 6

Is This Answer Correct ?    3 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2312


Hi sir if any product monograph not given known impurities (may be 5 impurities) specifications then how we require to proceed for inhouse formulation?

704


on the basis of bcs class how to proceed the solubility?

769


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

785


Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

2718


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1817


why cone formation during dissolution?

782


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1596


How to do regeneration of Metacarb Pb plus column?

2579


In which situation we require to analytical method validation of excipient?

786


which are the sizes of capsules?

964


Why six unit used for precision?

1347


What is the Formula for coreletion coefficient in plhplc calibration

1825


What is mean by PDR?

941


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1971