what is plc?
Answer Posted / priyanka
A PLC (i.e. Programmable Logic Controller) is a device that was invented to replace the necessary sequential relay circuits for machine control. The PLC works by looking at its inputs and depending upon their state, turning on/off its outputs. The user enters a program, usually via software, that gives the desired results
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is intrinscily safe system and where we use?
what is dc moter.
hey any one got the papers of SAIL and HPCL plz do help me by posting them to my mail ID's naren07_87@yaho.co.in, surenarendra@gmail.com
what is scale factor of proximitor & unit of the vibration.
How to work temperature gauge?
how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr
what are the use of belew gear in general ??
For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
How does a single acting, spring return ball valve actually work? Does it require continuous air supply?
key exchanges in wpa,wpa2,tls
what will the sending unit in the fuel gauge utilizes?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
can anyone tel the syllabus or previous year question paper for BHAVINI(EIE)2014.
In dcs panel we are using diff type of modules ?what is module ? what is the use of modules ?diff type of module?
what is the difference between magnetic flow meter and mass flowmeter