Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why do we use around only 60 mg of K2cr2o7 in the UV
calibration -control of absorbance test?

Answer Posted / vishu

K2cr2o7 cover both uv and visibale range therefore use for calibration

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why perchloric acid used for potentiometric titration

2631


USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...

1968


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2669


What is third generation HPLC Columns?

1934


what is turbidimetric titration?Give 2 examples.

2580


Why Ethanol is Used for Standardization of GC Head space?

4156


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1791


1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2829


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3119


Ph meter can show more than 14 ph reading? Why ph range in between 1 to 14 only?

687


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3620


mahagenco syllabus for the post of chemist

6426


analytical method validation require to with respect to release specification or shelf life specification?

733


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1744


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4003