Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

we run the same sample in same method in different flow rates
in HPLC,any changes in sample analysis?

Answer Posted / uvreddy

changes are there,because flow rate increases closely peaks
will merge,flow rate decreses some time closely peaks will
come better resolution.

Is This Answer Correct ?    12 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

3550


In Dissolution Test why limit is define Q+5% what is the role of +5%.

3153


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

2359


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1649


[3/28, 20:52] Manoj P Venkatpurwar: how many impurities require to inject in assay specificity that how we can find out? and in Rs also how?

838


Why six unit used for precision?

1397


why we should take dst factor for below 1%moisture samples

2713


A ha tc is actual defination of retention time?

1662


Did anybody have method for acetyl cysteine effervescnce tablet

2296


which are the diffrent batches in the pharmaceuticals?

859


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3221


identification is for unknown? qualification for known? reporting for LOQ?

774


4. Describe the operation of the Craig apparatus. Chapter.3 Equilibrium Processes in Separations

2768


in which situation ion pair require to use?

876


Which parameter require to do for analytical method equivalency?

817