What will happen if 230V DC motor connected to 230V AC
Supply?

Answer Posted / parikh snkp

it will work...coz in the nextcycle both field and armature winding both will be in reversed direction so by this we can get same side rotation ........i mean to say unidirectional rotational

Is This Answer Correct ?    3 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

The power supplied to a 50mH inductor from a 120V, 60Hz source will be

4244


What is meant by reactance voltage?

635


If only R Phase is connected in 2 pole elcb, n is not connected than it will work or not in ground fault.

994


How much no load current of synchronous motor

1598


What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.

904






WHAT IS DEGREE OF COMPOUNDING IN D.C MACHINE MEANS? HOW TO READ THE OPERATING CHART FOR ANY ELECTRICAL MACHINES?

4277


In a 3 phase 4-wire system. For a 3.5 core cable if all loads are single phase and balanced, what will be neutral current? will it be sum of all phase currents? Or it will be zero? And if loads are unbalanced what will be neutral current?

1258


what's the difference between 'shaft power demand' and 'BHP' , when we consider electrical load list.

1089


dg earth connect only in the amf panel or not why

1606


1 “earthing” for bonding of equipment and circuits to common plant earth electrode potential, 2 “protective earthing (PE)” when this bonding is required for personal safety provisions 3 “grounding” for interference suppressing bonding of screens, sys-tems with ground level 4. low-impedance earthing ? 5.primary earthing system and secondary earthing system what is that? 6.earthing electrode or mesh net earthing electrode ? very confusing , simple but very informative help required ? i will be very very thankful to you guys.

1612


please send previous exams question papers

1402


why we are not giving the zone 1 trip command to the master trip relay

1084


Dear Brother can u tell the proper size selection of cable & the fault level calculation of braker, busbar etc. pls mail me at azeemk30@gmail.com

1441


What is the effect of solar radiation on the design of an Isolated Phase Busduct?

1874


Give accurate definitions for these electric terms: Inductor Inductance Inductive Induction Reactance Reactive Esam Baraka ٢١ ساعة

922