Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How the cable size for a motor is decided

Answer Posted / anil saini

the cable size of the motor is decided on the basis:
1 the rated current of motor
2 starting current of the motor (reason:-might be very high)
3 considering the fault current flow in case of fault
4 starter we are using to start the motor
5 considering the cost of insulation required for the cable.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS DOL STARTER? HOW IT WORK? GIVE ITS CONTROL AND POWER DIAGRAM .

2171


Why we are use dol starter up to 10 hp

1374


I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?

1747


why on axial hitting up of air blast on hydrogen produced in oil circuit breaker,temperature rises of the core of the arc?

1964


In Indian Household, generally we receive 220V AC single phase supply. But AC has 2 phases, +ve & -ve. So in +ve half cycle current is flowing...so what happens in the -ve half cycle?? Please illustrate.

2031


what are the difference between AC lamp and DC lamp

2096


in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses?  the second question is-generation is depends on LV winding? or LV winding design for generation voltage?

1740


What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)

3649


HOW TO REDUCE POWER PLANT AUXILIARY POWER CONSUMPTION?

3416


why ten delta testing is carried out on power transformer

1816


Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????

2002


How to calculate that clean water supply in one Day from 150 KLD STP?

2009


actually i can't understand what is 3dB ? and it's really not clear to me.please any one let it me be cleared.

2252


How Diesel Generator start ?

2414


What are the advantages and disadvantages of closed-loop control system?

1184