Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In a coal fired boiler furnace temp. is high but super
heater out let temp. low what reason for this?

Answer Posted / k.p.selvakumar

1.super heated coil have any leak or puntcure.
2.continousely opened condition of attemperator valve.
3.opened all turbine draine valves in trip condition.
4.forced draught fan tamper open value high.
5.operating problem having in super heater outlet valve to main sream line.

Is This Answer Correct ?    0 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

2482


procedure of how to generate power in solar plant.

2024


why airtel use + 24 volts and other operators use -48 volt

2692


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1973


How to calculate power press toneage

2129


what is natural frequency of turbine shaft .

2365


LAPT working in alternator / generator

3694


what is the difference between compensated & normal drum level in boiler drum?

1860


By any way can we increase the B check hours from 300 to 500

2254


How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.

2357


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1752


can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

1794


what is the basic use of power plant in equipment

1841


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

1046


Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.

3467