In a coal fired boiler furnace temp. is high but super
heater out let temp. low what reason for this?

Answer Posted / k.p.selvakumar

1.super heated coil have any leak or puntcure.
2.continousely opened condition of attemperator valve.
3.opened all turbine draine valves in trip condition.
4.forced draught fan tamper open value high.
5.operating problem having in super heater outlet valve to main sream line.

Is This Answer Correct ?    0 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is LB-SR.

2483


what is restricted earth fault explain in details

1622


what is the trip circuit supervision in an electrical meaning?

1441


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1229


Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon

1765






What is difference between secondary Air & Tertiary Air and Their use.?

1474


what is natural frequency of turbine shaft .

1720


can dp type level transmitter work in under vaccum condition

1533


Why superheated are started before I'd and rd fan?

1692


what's the moog valve

1050


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

1936


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

514


How do you consider that you can improve and what assistance do you need to achieve this

1332


operation

1374


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1428