Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between the ordinary loss on drying
technique and vacuum oven technique?

Answer Posted / madinenikiran

WE SHOULD USE VACCUME OVEN FOR THOSE COMPOUNDS WHICH HAVE
THE MELTING POINT BELOW 100C. IN THIS METHOD WE USE
PRESSURE AT 60C. THIS IS EQUAL TO 10 TIMES HIGHER THAN THE
TEMPARATURE WHAT WE APPLIED(60C).FOR THE COMPOUNDS WHICH
HAVE MELTING POINT ABOVE 100C, WE USE LOD OVEN

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

864


How do we fix the sample concentaryion in hplc method development. What is the basis?

1211


Why six unit used for precision?

1357


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

3486


CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

1213


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

1604


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

9806


4. Describe the operation of the Craig apparatus. Chapter.3 Equilibrium Processes in Separations

2725


if tech transfer fails whay require to do?

851


Did anybody have method for acetyl cysteine effervescnce tablet

2256


How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

4280


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1973


How to calculation of residual solvent methanol (3000 ppm) standard solution, and how many quantity used of test sample

3248


We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1722


What is the difference between chromatographic purity and related substances?

1380