Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why urasil use in hplc column perfomance?

Answer Posted / palanisamy

In reverse phase chromatography Uracil compound more
ratanied in mobile phase,it will elute first so we are
calculating capacity factor taking void volume for this
uracil peak

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2732


how pda detector works over uv?

744


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

2607


How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

4279


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1601


if you get peak in blank then what require to do?

979


on the basis of bcs class how to proceed the solubility?

786


what are the standard methods for HPLC?

2787


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2224


What is Band broading effect explain

1886


if peak get problamatic then what require to do?

805


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2874


how you determine moist.of NaOH sol or NaOH flacks

2223


how to decide for one product require water content or LOD?

787


How to set analyticl specification for combination products?

750