Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Difference between ups

Answer Posted / mohamed nizar

The difference's between an inverter and a UPS are as follows

1) CHANGE OVER TIME: An off-line ups (the standard) switches to the batteries in 3 to 8 milliseconds, after the main power has been lost.
The typical Inverter changes over in about 500 milliseconds

2) SIZE: Off-line UPS's go up to about 2kVA
Inverters go to 16kVA, 3 phase(what i could find browsing)

3)VOLTAGE REGULATION: UPS's have automatic voltage regulation (AVR) set on average at 220v
Inverters output voltage is the same as the mains input voltage (South Africa = 230V)


An inverter can transform a voltage from say 12volts dc and up to 230v AC.
UPS means Uninterrupted Power Supply. If you use an UPS between your computer, and your socket in the wall, and experience a power failure, the UPS will act as a battery and give you some extra minutes work time to save your work, and turn of the machine properly. Without the UPS your machine would die immediately.
*note: the UPS is NOT a normal battery, so you cant put a battery between your computer and the mains.



2) The basic

difference in layman's terms is:

While both provide backup power during mains outage, with the UPS the switch is instantaneous whereas with the Inverter there is a gap of a second or two. This gap is OK for household gadgets such as lights, fans, fridge, etc. but not OK for computers.

In technical terms:

UPS: The mains power comes to the UPS. The AC is converted to DC and this DC is constantly charging the battery. The output of the battery is fed to the Sine wave inverter and it converts DC to AC and this feeds the equipment. Since power out is always drawn from the battery, there is no time lag when mains switches off; it just stops the battery from being charged and the UPS continues to supply power till the battery runs out.

Inverter: The mains powercomes to the Inverter. This is directly sent to the output but the AC is also converted to DC and this DC is constantly charging the battery. A sensor and relay mechanism checks whether the mains is ON or OFF. When the main switches OFF, the relay actuator triggers to switch from mains to inverter. Rest is same like the UPS. Because of this sensor and relay, there is a gap between triggering.

UPS involves more costly circuits and is therefore more expensive to make and sell.

Apart from these there is another difference. The AC supply has a pure sine wave whereas in an offline UPS the output is a near sine wav, not a pure sine wav where as for a inverter its step wave. This is the reason that we hear a hum when we attach a inductive load to a UPS or a inverter but we do not hear anything when its on AC supply.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What aturn on methods of scr?

1243


I have 1500/1A CT If i connect this CT in 6.6KV bus bar means what will be the voltage present in CT?

2087


From reading, Under voltage relay used also as phase sequence relay now, Why I use under voltage and phase sequence relay in the same circuit (ATS)?

1836


Air refrigeration cycle works on the

1158


Earth is a conductor or load?then ammeter connect to 3- phase supply,it shows the measurents or not?

2149


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

2316


1.WHAT IS A SMART CAPABLE DB ( DISTRIBUTION BOX) ? 2. HOW TO DECIDE THE TYPE OF DB TO BE USED ( RECESSED/ PLUG TYPE/ SMART ETC ETC? 3. WHAT IS MILLENEUM BUS BAR USED IN DB? 4.DIFFERENTIATE MCCB AND MCB.

1897


Whether amorphous core transformer is available in India?.If available then up to what rating of voltage and KVA?.

1804


which cable is used for 15 Hp monoblock pump 3phase and service wire Distance is 210 feet please tell me cable size Armaured

1658


What are hrc fuses and where it is used?

1240


Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.

2016


why Current is lead 90 degree and voltage is lag 90 degree in a capacitor.? why Current is lag 90 degree and voltage is lead 90 degree in an inductor.?

2331


How to select cable the size, what is the parameters use and what is the formulas use for this cable size calculation?

1976


any one please tell taht what type questions will be asked in BHEL interview, i am having interview on 24th Dec, please send this to mail pradeepsistam@yahoo.co.in

2063


What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.

2650