Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the Bracketing & Matrixing.

Answer Posted / a s n kumar (makson industri

.Both Matrixing & Bracketing’s are reduced stability testing designs
Bracketing
The design of a stability schedule, such that only samples of extremes of certain design factors (ex:strength,package size) are tested at all time points as in full design.The designs assumes that the stability of any intermediate level is represented by the stability of extremes tested.
Matrixing
The design of a stability schedule, such that a selected subset of possible samples for all factor combinations is tested at a specified time point.At a subsequent time point another subset of samples for all factor combination is tested.The design assumes that the stability of each subset samples tested represents the stability of all samples at a given time point.
There for a given time point other than initial & final ones not every batch on stability needs to be tested.

Is This Answer Correct ?    5 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3721


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1895


for inorganic molecules require to do RS, Assay and disso?

774


what is the importance of peak purity in HPLC and how we can calculate through manul(not software)?

4531


what is the structure of DOWEX-50

5557


if your product is soluble in 0.1n hcl and water then which you choose as media from these 2 media?

730


which situation gc hs and gc als require to use?

835


what parameters we will consider while developing a HPLC method and how we confirm our HPLC method is valid?

3747


Which parameter require to do for analytical method equivalency?

816


how can I make the copper get white bye any salt or acit?

2264


how pda detector works over uv?

777


in OSD forms require to use gas chromatography?

864


why xterra column require to use at higher ph?

966


how to develop the icp ms method? Application of icp ms?

844


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

2093