Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

A new drug substance found fail to meet specification for
an unknown Impurity during stability study(Specific
change),how would further proceed?

Answer Posted / chinna

if the sample failed in accelerated condition we go for long term storage condition.if it fails in long term stability we go for OOS and give to retest/Expiry as per ICH guideline

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

iam usig ph buffers merk. manually how to prepare ?

2223


In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.

3072


Loss of linearity in tkn analysis, possible reasons?

1256


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1792


how can give the expiry period and restadardisation of volumetric solution

2530


How to set analyticl specification for combination products?

689


what is the structure of DOWEX-50

5454


mahagenco syllabus for the post of chemist

6429


in OSD forms require to use gas chromatography?

778


how you fix the limits of impurities?

788


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

2900


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1806


How do we get end points and how many end points are possible for citric acid and di-acid not theorotically answer should be given practically.

2542


What is split ratio in Gc? Splitless? how requirr to select?

820


how to decide for one product require water content or LOD?

726