Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is difference between oos

Answer Posted / archana

OOS(out of specification) means the result that fails to comply with given specification during analysis

Deviation means any planned or unplanned departure from GMP
e.g Wrong quantity of raw material is added,wrong sequences of addition of ingradents in manufacturing process,wrong process time is followed etc

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1546


In rs method development when we are going area normalization method to dilute standard method?

1473


what you do when compound having dwel wavelength?

702


how you confirm the assay method?

722


How much is the standard area for glc analysis

2209


which are the sizes of capsules?

887


in hplc chromatogram started from left to right and in uv spectrum started from left to right

889


Principle of single pan analytical balance

5084


why holium oxide prepared in 10% HCLO4 SOLUTION

1404


sop of a uv visible spectrophotometer double beam elico model

5861


if instrument calibration fails then what require to do?

893


in sampling of raw material which side is pasted sampled labels

1778


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

2249


what is mean by peak intigrity?

862


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1906