Answer Posted / balki
UPS- EB source is converted to DC power through rectifier(DC
to AC), this connected to battery and to Inverter(DC to AC)
this AC supply can be fed to load in this case even EB power
failure the power will be fed to load from battery to
Inverter to load. So there is no power interruption to load
thats why it called as Uninterrupted Power Supply.
Inverter- EB source is converted to DC power through
rectifier(DC to AC), this connected to battery and to
Inverter(DC to AC). At normal EB power available time the EB
source directly fed to Load, If EB power failure the switch
will be activated and stored power in Battery will be fed to
load(battery to Inverter to load). So there is a power
interruption(less than 20 Sec) to load.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
why EMF IS INDUCED IN A CONDUCTOR WHEN FLUX LINKING WITH IT CHANGES ACCORDING TO FARADAYS LAW.
how we calculate the dick for a pole?
Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?
What is float cum boost charging system?
i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester
What are the temperature elements?
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
What will happen if the d.c. Shunt motor opened accidentally running on no-load has its shunt field winding?
what is meaning of sympathetic tripping with respect to relays and give the values for current carrying capacities for copper and aluminium cables from 16sq mm to 500sq mm
what is the safety of voltage power transformer(2250KVA0
How I can Compare 120v/60Hz versus 220v/50Hz ? Please tell me both advantage and disadvantage ......
In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.
Why space heater is required for each verical bus bar chamber? if one space heater is adequate or not for anti condensation?
Why the moulded plug comes with domestic appliances instead of assembled plug like anchor, Vinay 5/15 A.
Define the overload capacity of the motor?