Answer Posted / charankumar
We are using 4 -20 ma because we will get linear current
with respect to 24 V,so i most of cases 4-20ma is used.
If u want to try plese plot a graph and check.
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
how u choose thermowell lenght n pnumatic C/v size?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .
i have done DAE in Instrumentation and Process Control. i have applied for an apprentice training in chemical company after three day my interview will be conduct but i need more information about industrial process control and controller. my e mail is imran_dilsetu@yahoo.com please tell me interview question relative to instrumentation ?
why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.
what is the difference between Cv and air consumption? why the customer needs Air consumption details?
What is furnace draft control?
Calibration procedure for Electro magnetic Flow meter
Explain plc level and its type?
What is standard procedure of manual mapping in Radar type level transmitter?
Give Detail information about plc,dcs,and scada system?
What materials are used in thermo wells?
How to control flow variations in magnetic flow maters..... When i will provide proper earthing?
what is the process to make control schematic ?