Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between Chromatograhic Purity And
Related substances

Answer Posted / gs

In Sample way, Related substance (RS) are associated with
Raw material (API/Excipients)that comes along with desired
raw material either known and/or unknown and Chromatographic
Purity means identified as known and unknown.

Is This Answer Correct ?    2 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is similarity factor and its use in api strength?

1295


Did anybody have method for acetyl cysteine effervescnce tablet

2238


What is aggregate and fragments in SEC?

2104


What is related substance by HPLC impurity limits as per USP?

1098


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1592


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2576


How to calculation of residual solvent methanol (3000 ppm) standard solution, and how many quantity used of test sample

3226


for inorganic molecules require to do RS, Assay and disso?

729


how the compound separate in coulunm,explain

2524


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

848


what is the extinction coefficient for Indomethacin or at 319nm wave length.

4065


what is the purge flow & how to calculate

2638


Why we check moisture,ash & AIA in product

1872


Why perchloric acid used for potentiometric titration

2674


why digestion require in icpms?

766