Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Is LV shorted in magnettic balance test?If yes why?

Answer Posted / tanmay kumar

generally magnetic balance test was done in transformers to know the ratio that means to check its rating whether it is giving the output or not as per the rating,,,in case of magnetic balance test the voltage feeded at the primary side always i.e l.v side and the secondary side is at no load i.e open ckted and a tongue tester is used to measure the amount of flowing current from primary to secondary.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2141


What's mean HVF & HAF in Vacuum Circuit Breaker?

5322


Which do you think is the most significant cause of energy loss in a factory?

2223


Ratings of power transformer,Distribution transformer.

1591


Iwould like to know barc interview questions

3213


Can i use the B-curve MCB instead of C-curve MCB

2011


IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?

4105


What are the basic elements used for modeling mechanical translational system?

1097


what is transistors comprised of?

1148


Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.

2640


what will happen if OLR CT in all phases are short circuted

2174


If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines

1624


working principle of AC Servo Motor with its construction

8869


how to calculate transformer turn primary & secondary side 11kv to 420v

2188


Explain advantages of storage batteries

1089