Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how we calculate the 30 KW 3phase electric motor current on
noload

Answer Posted / darshana sharma

At no load 30 kW, 3 phase electric motor will draw 30% to
40% of full load current.

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate Air conditioning capacity for a telecom BTS shelter?

3499


with out colour codeing on conductor how can be find what is r,what is b,what is y phases.....

1942


3phase motor can be used as a Prime mover for alternator.

1591


What is the function of RCBO? What are the different sensitivity ratings & each application?

2807


For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?

1893


what is earthing.how we make it,describe briefly.

2612


why transmission is only 3 phase and not 2 or 4 or poly phases

2120


Q.1:What protection will be used on HT and LT side of 33/0.4 KV, MVA transformer. Indicate capacities of protective device to be used. Q.2:Which types of back-up protections are used in the power transformers? What do you understand by the term over travel in the relay? Q.3:How star and delta connected winding transformer are provided from earth fault

2118


for 750 kw LT load what will be the ht kva

1643


reason of diode failure in alternator

1847


how can we say that stator magnetic field rotates with synchronous speed?can we derive?

1767


I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

4027


how to calculate cable size in diffrent loads?

2073


Why colled 440V to 3-phase supply.

2142


can the measured percentage error during calibration of single phase energy meter be negative?

2401