What is principle of Polarimeter?

Answer Posted / jyoti sood

When a beam of
monochromatic light is
passed through the
sample, it is rotated at
certain angle either
towards left or right
which tells about the
nature and purity of
the sample. This is
shown by only optically
active compounds

Is This Answer Correct ?    18 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Difference between hlaf and rlaf

1642


Why we check moisture,ash & AIA in product

1396


UV and PDA detector, which have less signal to noise ratio?

638


what is definition of validation? which components are followed give detail?

1826


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1105






2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

1755


how will you do the prep for unstable componds?

1433


If we do accuracy at same concentration at which linearity planned,what is the need to do linearity separately?

1750


what is mean by dissolution hydrodynamics?

342


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

302


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1448


for inorganic molecules require to do RS, Assay and disso?

245


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2311


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

1542


what are the guidelines for analytical method validations?

589