why we are using in ph calibrations ph4,7,9.2 buffers only?

Answer Posted / kishan patel (amneal)

Calibrations not limited to 4,7,9.2 it's should cover ur
analysis range i.e. minimum to minimum and higher to higher
( 1.68-12.45)

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2350


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

1771


what is the difference between potentiometric titration and karl fischer titration?

2431


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

1555


What is the diffrence in japan mkt requirement in analytical method validation over US?

302






what is the importance of peak purity in HPLC and how we can calculate through manul(not software)?

3996


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

1945


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

2963


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1380


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1362


How to establish relative response factor for hplc. Why it is required?

711


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1463


What is the diference between residual solvents and organic volatile matter

1502


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2232


Why Ethanol is Used for Standardization of GC Head space?

3724