Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why KBr is used in FTIR SPECTROSCOPY and why is it necessary
to triturate KBr during FTIR analysis?

Answer Posted / naresh

KBr on absorption of radition it excites only to vibrationl
energy level it does not get more energy to transmit to
higher rotatioal level so its not detected,and aid in easy
pellet formation

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How do we fix the sample concentaryion in hplc method development. What is the basis?

1204


How to determine water content of bis tetrazole amine mono ammonium salt

3484


which situation gc hs and gc als require to use?

783


how you start RS method development when for new product?

718


How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain

2387


Home heating oil or furnace oil what is made from? Can (base oil plus diesel/kerosen) = home heating oil?

2178


Difference between the quantitative analysis and qualitative analysis?

1172


How to know the estimated LOQ concentration in ppm

1209


How you develop a method in HPLC?

2614


what is mean by 40 in the dissolution basket mesh size?

784


How doing qbd practically?

976


How to fix the sample conc. in Related substances test by HPLC?

1094


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1595


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1977


what is the procedure for cleaning of lenses of hatr accesory of ftir instrument?

2289