Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why the generator rating in kva

Answer Posted / shahid siddique

As generator may be connected to any type of load(Inductive,Capacitive) therefore primarily it is independent of power factor,so we rating of generator which produces voltage and currents(v*i) is rated in kva, as motors have specific load nature (mostly inductive having specific power factor) are rated in kw

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What kind of maintenance is conducted for Transformer

2204


why generator efficiency is more in swinburnes test?

2153


what is the physical connection of a analog i/p to a analog i/p module (ab plc)and through a analog o/p module(ab plc) to a analog o/p . and how all the process control by scada

1870


sir, 3phase induction motor takes different pf and different KW in three phase while running,explain reason

1416


how ct burden,magnetising current,ratio and knee point voltage are related & derived

2148


What is the formula to calculate the rating of a three phase miniature circuit breaker

2077


What is meant by reset level of the relay?

1147


what is the formula for calculating the phase clerance between two phases and phase to earth how to calculate the cable for a motor

1948


What is the importance of counter based plan & how is it scheduled?

1967


What is Long rod insulator and it's applications..? merits over the disc insulator ..?

1852


Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?

1092


what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer

2043


what is lumped and distributed elements?

1897


what is self capacitance of inductor

2368


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1891