What is the main application of DUMMY COIL in machines?
Answer Posted / adeppa naik
for mechanical balancing purpose
| Is This Answer Correct ? | 30 Yes | 5 No |
Post New Answer View All Answers
What happen when change order of CT in GIS feeder?
how to test reverse power trip?
What is the importance of counter based plan & how is it scheduled?
how the inner and outer body is separated in aircrafts?
george phenomenon of synchronous machine
What is the difference between earthing,ground&nutral?
why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?
work of choke in florocent tube circuit ?
is there any phase difference occurs while primary and secondary side mutual induction occurs?
what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?
Is it a better option to procure screw type air compressor rather than reciprocating air compressor?If so, what is the reason?How should we select an air compressor(100 CFM)? Please mention the important parameters of air compressor.
How many sprinklers should be in one pipe line?
what is the difference between switch yard to residential area.and how much required it.
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What is the difference between type1 and type2 relay protection co-ordination for motor feeders