Volumetric solutions prepared in wet chemistry lab?
Answer Posted / pankaj punjabi
To establish retest or expiry date of volumetric solutions
we have to conduct validation of stability study i.e.
initial (day-1) ,7,15,30 days of intervals through a
protocol. based on results we can establish retest date of
volumetric solutions.
Suppose we wont to decide validity up to 30 days,we need to
conduct stability up to 45 days,if it's stable up to 45
days (physical apperance and strength) then we will give up
to 30 days validity.
Acceptance criteria : As per EP 6.0, RSD of three replicate
analysis is NMT 0.02%
| Is This Answer Correct ? | 3 Yes | 8 No |
Post New Answer View All Answers
USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...
Which products will produce when acetic anhydride reacts with Ter-butanol, Sec-butanol, Iso butanol, Dimethylamine etc.
what is mean by dissolution biowaiver study?
if you get peak in blank then what require to do?
why octanol used to determine the partition coefficient ?
As per ICH related substances stability trend limit from initial to shelf life
Explain the relations between number of carbon atoms in alkanes and retention time ?
How to know the estimated LOQ concentration in ppm
for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol
What is importance of pH in the Heavy metal test and How it effect on the test results?
why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?
How we can identify process related and degradation impurity in single method with short period?
Hi sir if any product monograph not given known impurities (may be 5 impurities) specifications then how we require to proceed for inhouse formulation?
in which situation require to take incident in validation?
what is partion and column chromatography