Answer Posted / a.narayana
Protocol means pre-planning report of the proposed
activities of execution.
Example: If plan for Process validation, we need to have a
plan to conduct the validation.
For this, we have write a full document, objective of the
validation, responsibilities, Starting materials and
related approved source deatils and analytical spec and
methods, In-process, Finished product spec and method,
Batch selection, Process BPR's and critical parameters and
formats for recording the results.
Another Example: In general, we plan for construct a house,
for this, we need to have a plan.
In this plan, firat we need a vacant site, approval,
material requirements, required amount, mason, wood work,
floor work, paintings, etc., If required amount, we need to
go for loan and related procedure ..
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
why octanol used to determine the partition coefficient ?
how you fix the limits of impurities?
Why irmoisture balance is used for corrugated box moisture testing
Ph meter can show more than 14 ph reading? Why ph range in between 1 to 14 only?
What is the difference between spectro meter and spectro photo meter?
What is the principle of Thermal conductivity detector and FID?
Why sodium hydroxide used for maintain pH of phosphate buffer
Qc interview questions
My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards
what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?
What is the principle of HPLC, GC, LCMS, GCMS,LC QQQ, GC QQQ, LC Q TOF and GC Q TOF. What are the applications and Specificity?
what is mean by extactable and leachable study?
what is the purge flow & how to calculate
Hi sir if any product monograph not given known impurities (may be 5 impurities) specifications then how we require to proceed for inhouse formulation?
Why perchloric acid used for potentiometric titration