what is difference between short ckt and overload?
Answer Posted / guest
when a load bypassed by a medium ,like phase to ground not
connecting load then electrons flow rate (amp) would be
higher enough to meltsdown the medium.Means load has been
shorted by passing all electrons to ground directly as by
not connecting the load.Overload means when machine ability
to run more than rated load, 1Kva transformer may have
rated load okva but if it reaches (1kva to 1.1kva) then it
is overloaded.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
what is the solution for meger test failed the MV cable?
prove that power consumed in 3 phase delta system is 3 times as compared to 3 phase star system
Can anyone tell me some hints about what type of questions are asked by the interviewer by an Electronics engineer when company is installing an IPP and wants a team of engineers?
what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator
how to modify DOL control panel into Delta Y connection?
In AC if the direction of current keeps reversing every half cycle, how does it propogate through the transmission lines?
Why r u using pf panel. what the uses
what is acceptable leakage current for 33kv cable while doing high voltage test for cable? how to calaulate the leakage current for 33kv or any rated cable?
if 3400kw slipring motor rotor shorting done and motor started on mv drive ,what will be the rotor shoring current
in electrical control panel. how can i choose the cable rating. (example - 11kw motor, 18-25A mpcb}
Please define ohm’s law for a.c (alternating current)?
What is the working principle of MIG welding? and its out put Voltage?
What do you understand by external characteristics of a d.c. Generator?
I want to know Electrical Circuit?