can we replace a pressure transmitter of range 0 to 25
Kg/cm2 by a Pressure transmitter of range 0 to 10
Kg/cm2 ?.. Will it affect 4 to 20 mA output signal which we
will feed to the PLC.
Answer Posted / imran
first of all you need permission to replace pressure tx
from operation instead 0-25 by swaping 0-10cause it will
effect process & may you r going to upset process other
point of view by technical you need to configure it & it
will give you output vice varsa
| Is This Answer Correct ? | 2 Yes | 3 No |
Post New Answer View All Answers
What is hp & mp seperator .& what is its working principle ?
KAlman filter code for two dimension?
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
There are many type of control cable like pair,core,tried, What are defination each one
What is force balance principle?
What is the diffrence between ff tx and non ff tx
how to work static pressure sensore how to work dpt
hye SAM acn u send your e mail id, so that i can solve my query through e mail?
why using negative supply for bentley nevada vibration system ?
Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?
What you mean by multi stage control vavles?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)
How can measure flow in oil line?which type of transmitter is generally used?
Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?