Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference b/w repeatability nd reproducibility ?

Answer Posted / sanju

As defined by ICH, reproducibility expresses the precision
between laboratories as in collaborative studies.

Repeatability expresses the precision under the same
operating conditions over a short interval of time.
Repeatability is also termed intra-assay precision.

Is This Answer Correct ?    30 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in which situation ion pair agent require to use?

799


what are the guidelines for analytical method validations?

1150


what are risk assement in the analytical qbd?

808


how to calculate elemental impurities?

1086


USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...

2071


if you have given one product then how you determine the impurity in that?

800


what is the extinction coefficient for Indomethacin or at 319nm wave length.

4125


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

2746


If suppose 10 methods of dissolution given in pharmacopoeial for single content product then which method out of 10? or all 10 require to follow?

1041


What is the formula for relative diffrence for standard solution in solution stability in validation?

863


in which situation require to take incident in validation?

1783


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1653


if peak get problamatic then what require to do?

861


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2624


cefoperozone and sulbactam inj. hplc test method

2746