How to calculate meter constant @ HT yard

Answer Posted / mohamed ali.m

My Dear This Answar.

Metering Constant.

PT Ratio x CT Ratio X Dial Constant/Meter PT Ratio X CT
Ratio

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

DC transmission

1595


what is the major difference between LIBBP & HIBBP.. which one is most preferable..

2010


What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP

1232


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

347


where reactive power is used

1552






Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

1746


why starting current is high and resistance is almost 0 during the starting of motor dc motor...?

1277


1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?

1749


What is the actual calculation for transformer short circuit test?.

1970


What is the function of the circuit breaker failure relay?

1888


why the colour of insultor stack , petticoat is brown. Is it has some technical reason.

1563


For R-L or R-C ckt,time constant formula is L/R and RC respectively and its unit is in sec.Pls tell me the derivation

2675


can anyone tell me can the electromagnetic waves can be reflected back?if so how &by which material it can be reflected back?please tell me so that it can help to my wireless power trasnmission device.

1346


In a flange coupling, the flange bolts are designed for

689


I have a small system with two motors that are running on 380 vac, 60 hz. These motors are expensive and I usally get them from Brazil. I am adding another motor to the system, but I want to purchase a 480 vac, 60 hz motor to use. It will be on a VFD that is rated fro 380 thru 480. Is this posible and will I have to use a larger motor and derate it?

1523