Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is pK & pKa value

Answer Posted / prashant

pKa=-log(Ka)... Ka=Ionisation Constant of Acid

pH=pKa+ Log[salt]/[acid]

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

2305


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2224


What is related substance by HPLC impurity limits as per USP?

1109


How to choose the which salt is suitable for mobilephase

3252


why require the ph, buffer during hplc mobile phase?

867


for which product require to do content uniformity? what is limit of cu?

821


what is mean by nitrosamine impurities?

1069


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1982


Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc

1471


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1600


all types of questions asked at the cipla interview

4686


Difference between the quantitative analysis and qualitative analysis?

1184


Please tell me about the pH of Polycaboxylic ether is it in the 5-6 range ever or more than 6

2609


Qc interview questions

1746


UV and PDA detector, which have less signal to noise ratio?