Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why caffeine as a reference standard used for calibration
of HPLC?

Answer Posted / srinivasarao yemineni

1. Maxima at 205 nm
2. Minima at 245 nm
3. Maxima at 273 nm

Since it is a universal known standard.
It is stable and easily available in the market.

But here comes the question how about the calibration of
wavelength accuracy at Visible range. In this case we can
use Erbium Perchlorate which will scan the whole range(200
nm to 600 nm).

It is stable and little costly but availability in the
market when compared to caffeine is litte tough.

Thanks for Marking this Answer

Is This Answer Correct ?    6 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to choose the which salt is suitable for mobilephase

3246


How to decide assay range for non pharmacopeial API analysis by HPLC? Could you give me any reference for same e.g Guidelines or Paper publications?

3353


What is the difference between purge septum flow and column flow in gas chromatography?

2581


Tell me about analytical method validation in QC

6175


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

6070


Loss of linearity in tkn analysis, possible reasons?

1315


WHAT IS THE USE OF STARTER ?????????

2422


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

854


give clarity of linearity and range in method validation

2418


What is similarity factor and its use in api strength?

1297


why are measure gas flow " ml " in Gas chromatography

1659


What is the diference between residual solvents and organic volatile matter

2042


Why dissolution test is not performed in all of the products

2535


What is the formula for relative diffrence for standard solution in solution stability in validation?

796


What are usp limits for theoritical plats,resoution,tailing factor,peak to valley ratio

1897