why we use only 4 to 20ma other than 0 to 16 ma

Answer Posted / farooq ahmad

Because we want to check the tx is damaged or not.If it
will be normal & no process variable applied then we can
get o/p 4mA...if it will damaged then o/p will not show 4
or near about..

Is This Answer Correct ?    5 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the exact differences between HART,FOUNDATION FIELDBUS,PROFIBUS?

3001


what is a half wave, full wave, and bridge rectifer.

1254


How would you choose differential range?

704


Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?

1489


What you mean by multi stage control vavles?

1378






What are the application of bernoulli’s theorem?

684


Difference between 2-Valve Manifolds, 3-Valve Manifolds and 5-Valve Manifolds 3 with diagram

2684


IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?

1756


what is the difference between -24 : +24 & 0:24 and where it use?

1630


If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1025


what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?

1754


how 3 out of 2 Logic/interlocks works? give brief explanation with help of diagram.

1840


please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com

1235


How to calibrate radar type level transmitter for interface level? Total liquid(liq.1 and liq.2), level both the liq individually? For. Both the liquid levels how the signal will go from transmitter to dcs? How to calibrate. Single radar 9:26:55 AM for 2 different liquids in a tank?

1577


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1138