Can u explain : what is supply for train (whether a,c or d.c
).I know that supply is 25000v a.c .But there is rumour that
supply is D.C.
And also explain how lights and fans inside the trains are
working ,and what type of motors are used in trains whether
D.C motors or induction motors .If d.c motor, how it gets
supply.If traction motors are used then what are traction
motors and its functions and how it differs from other
motors and also explain about locomotive .
please reply..............
Answer Posted / sharan dilip
dc shunt motor are never used for traction.
it has drooping characteristics of Torque Vs Speed hence dc
shunt motor is not employed.
The characteristics of dc series motor suits best for that
application. its better if you observe the characteristics
of dc series motor.
| Is This Answer Correct ? | 13 Yes | 0 No |
Post New Answer View All Answers
we have 15 ampere variyac but we want 30 ampere variyac what we do
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
number of I/O devices in siemense plc
Draw a circuit diagram in which if button is open we can use socket and bulb as a series test circit and if button is close than simple we can use socket as any load purpose.
what is the function of impulse relay
What is the IS standard for MCCB to be use (As per capacity of AMP)& for ACB also.
if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .
induction 3 phase motor terminal connection
can you any one give exact mathematical relation between AC current and DC current?
CAN WE CALCULATE THE NEGATIVE SEQUENCE AND ZERO SEQUENCE REACTANCE OF A GENERATOR USING ONLY ITS RATED VOLTAGE, KW, PF AND SYNCHRONOUS REACTANCE??? IF YES, THEN HOW??
Explain in brief description about the operation of DG sets.
WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?WHAT IS THE NEED TO BE PHASE SHIFT CHANGE BETWEEN THE PRIMARY AND SECONDARY WINDING
Earth bits close or open. Which is correct
at what rate the micro controller increment its timer....is it 1micro seconds or 1/(12*10^6) seconds
i need the curve duty cycle and amper for (150 kva @50% dyty cycle) transformer turn ratio :19 and vin 400