Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are peak purity,peak purity index,peak thresold

Answer Posted / sheetal

Agree with the above answer but the minimum allowable
variation range should be (purity
threshold ) greater than that of measured value (purity
angle) then peak purity passes.If not it will fail.

Is This Answer Correct ?    14 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1673


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7475


Basic principle of ESI?

2096


How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

4150


WHY pKa value is more important than pH value of the mobile phase in HPLC?

1713


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3487


how to decide for one product require water content or LOD?

723


What is the diference between residual solvents and organic volatile matter

1963


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

1985


If we have 5 strength which is not dose proportinate and excipients also diffrent in each strength then how we can proceed for Force degradation? and excipient are same but not dose propotinate the how FD?

758


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2171


what is definition of validation? which components are followed give detail?

2292


why does used dry caffien in HPLC calibration?

1983


how the compound separate in coulunm,explain

2444


What is diffrence between extractable volume and deliverable volume? Answer pls

4497