what is principle of DC machines?
Answer Posted / raja
2 principles
1 is hetropolar
In the case of a hetero-polar generator the
induced emf in a conductor goes through a
cyclic change in voltage as it passes under north and south
pole polarity alternately.
2 is Homo polar
Even though the magnetic poles occur in pairs,
in a homo-polar generator the conductors
are arranged in such a manner that they always move under
one polarity. Either north pole
or south pole could be used for this purpose. Since the
conductor encounters the magnetic
flux of the same polarity every where it is called a homo
polar generator.
| Is This Answer Correct ? | 7 Yes | 4 No |
Post New Answer View All Answers
How many types of circuit loads are there in a common electrical circuit?
What is the loss of transformer of 220kv/11kv, 63/80 MVA and 18.05% impedance
As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.
when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you
How many double suspension hardware fittings are required on a double circuit transmission tower?
Draw a circuit diagram in which if button is open we can use socket and bulb as a series test circit and if button is close than simple we can use socket as any load purpose.
What will be the diameter of pipe between conservation tank and transformer
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
what kind of technical test that i need to learn because i have an interview tomorrow.. please someone help me..
What is the Minimum winding resistance of motors ( small & big)? referance range
we have 3.5MVA-11/6KV transformer. how can we calculate earth fault current and NGR calculation?
State the methods of improving power factor?
what is the soft starter principle? how is connection diagram? what is the procedure for checking the connection?
Why is voltage is required to be within permissible range for an electrical equipment?
what is relation between ct and pt ratio with multiplication factor of a energy meter? is there any other factor on which multification factor depend?