Can we use MVC instruction to move pack field to pack
field....which instruction you will use and why ?

Answer Posted / steve holton

Qualification to above answer:

You can use MVC to move ANY data from any addressable
storage area to another. So the answer above is correct.
But if you use this technique, it is up to the programmer to
ensure that the result is valid. For example, the source
field may not be the same length as the target, so any
subsequent decimal arithmetic calculations (after a
"straight" MVC FIELD2,FIELD2) against the target field could
result in abend (S0C7). Even if the source field IS packed
decimal, if it is of a different length than the target, the
programmer will have to "adjust" the source and target
specifications to ensure that the result in the target field
is valid packed decimal. For example, if the source field is
PL3 (packed length 3)and the target is PL5, a "straight" MVC
PL5field,PL3field will leave 2 bytes of "garbage" in the
last 2 bytes of PL5field (assuming that you don't get an
abend S0C4 because the and of PL3 is at a page boundary).
For this case to work, you need MVC PL5field+2(3),PL5field,
then you need to ensure that the "top two" bytes of PL5field
are zero to ensure that subesequent packed decimal
arithmetic using PL5field will work.

Is This Answer Correct ?    14 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is icm instruction?

637


What is need of start 0?

653


Explain the difference between various read and find statement?

617


How do you round the addition or subtraction of two numbers in assembler?

602


Why do we use "drop"?

561






What is maximum displacement?

619


Explain about house keeping in assembler?

632


What is maximum displacement and how to cross this limit?

662


how to initialize a register to 0000?

663


In the house keeping section of an MVS assembly language program, like the one below STM R14,R12,12(R13) BASR R12,R0 USING *,R12,R11 LA R11,2048 LA R11,2048(R11,R12) .... .... 1. What if BASR R12,R0 IS NOT PRECEDE USING *,R12,R11? 2. USING (base address), REGISTER does USING directive says assembler to treat particular Register as a base register with the mentioned base address..in the above case * i.e current location counter..well if that is the case why we need BASR R12,R0 ? 3. What if I write like STM R14,R12,12(R13) BASR R12,R0 LA R11,2048 LA R11,2048(R11,R12) USING *,R12,R11 there is no address resolution being calculated in both LA statements so is it a right way to set Base register?..will there be any issues with Domain regarding R11 and R12?

1524


how to retrieve the instream data in sysin?

675


Explain how to produce soc7 abend?

633


Explain about maximum displacement?

603


Explain how to pass instream data in sysin with assembler?

640


What does the following code do? Ap wkur,=p5 where wkur is a label?

610