What is the rating of HT SUBSTATION and LT SUBSTATION?
Answer Posted / prasad joshianwikar
Firstly the HT Means High Transform,LT Means Lot Transform
in our country the regular pattern of ss distribution is
440KV DC Input from generation places then at 440KV DC is
then converted in AC afterwords AC is stepen down to 220KV
to supply the 132KV SS, the 132SS Stepen downs it in
66KV,33KV and 11KV. as in specific manner not a substation
is LT it is always HT because all the substations are
working on KV's i.e.220/132/(66/33)/11 supplies. in case of
the industrial supply the bill of consumption is always
issued as HT Customers with consmption of HT KWh units rate
hence not a substation is LT. as in final the 11KV line is
transmitted to each LT Transformerwhich has three inputs
and four Outputs that are the actual LT's. if you properly
observe the HT Lines 220/132/(66/33)/11KV's are only of
three inputs and not the neutral with them and in the SS
the transfomers that are used for StepDown process are also
of three input and three output and no presence of neutral
their, and uses the DELTA to DELTA transformation with
varying no. of turns on PRIMARY & SECONDARY with On Load
tap Changer for voltage controll. hence in rough the HT
lines not uses the neutral and the ss too hence not a
single SS is LT all are HT in nature and main is that, when
11kv is stepen down at pole transformer which is DELTA-STAR
in nature takes input as 11KV three phase R Y B ar DELTA
and gives R Y B N i.e. three phase with NEUTRAL(N) are the
LT. LT has 440VAC between Phase to Phase and 250VAC in
Phase to Neutral. thats the LT line. all the substations
are HT coz they supplies Voltages in KV's i.e.1000's of
voltage between Phase to Phase. and not the 440VAC between
Phase to Phase and 250VAC in Phase to Neutral. hence all
substations are HT and not LT in nature. but lines that
carries the voltage only.
| Is This Answer Correct ? | 12 Yes | 7 No |
Post New Answer View All Answers
HOW TO CALCULATE THE VT SIZING?
What is the difference between Generator Differential Relay and Transformer Differential Relay?
Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com
Explain (in simple ) - root mean square. whats its role in electrical fundamandal.where its used
How you calculate the repturing capacity of a HRC fuse
What range of speed can you get with the field control method of speed control of d.c. Shunt motor?
How the PF control while running DG set with load
What is core CT & it's function?
what is the use of vcb & isolator in substation?
Difference between Earthing Truck & Earthing trolly for HT panel
how to calculate the torque of a motor?
plz tel me syllabus and exam date 4 jr executive engg (electrical)
what is the function of choke in the flourcent tube lights and why the colour is in white mostly in flourcent tube lights
what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?
we use 400/5A ct and 35/roor3KV,/0.1/root3KV,0.1/root3KV pt ratio. What is the multiple factor of this meter.