Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE USAGE OF REFRACTIVE INDEX IN PHARME FIELD

Answer Posted / swathi.k

every compound has its own refractive index from dat v know the quality of the compound and based on RI V can analyse the samples by hplc.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1614


what is mean by ambient temperature?

905


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2837


Why potassium dichromate is used in calibration of uv?

1972


What are the primary considerations in extractables and Leachables ?

2261


what is mean by extactable and leachable study?

1146


give clarity of linearity and range in method validation

2405


in hplc chromatogram started from left to right and in uv spectrum started from left to right

934


how can I make the copper get white bye any salt or acit?

2194


Related substance method equivalency on control sample or spiked sample?

751


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1580


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

759


could negative ions be produced by bombardment process in mass spectrometry?

1761


why require to add enzymes in capsules dissolution only? is it require to tablet also?

669


What is related substance by HPLC impurity limits as per USP?

1079