from which formula we select a capacitor rating?
Answer Posted / dhinakaran.s
capacitance is the ability of a body to hold an electrical
charge. Capacitance is also a measure of the amount of
electrical energy stored (or separated) for a given
electric potential.
Capacitance is given by C = Q/V farad.
The SI unit of capacitance is the farad; 1 farad is 1
coulomb per volt.
In parallel plate capacitor,
C=εA/d farad.
where
ε=ε0*εr
C is the capacitance;
A is the area of overlap of the two plates;
εr is the relative static permittivity (sometimes called
the dielectric constant) of the material between the plates
(for a vacuum, εr = 1);
ε0 is the electric constant (ε0 ≈ 8.854×10−12 F m–1); and
d is the separation between the plates.
| Is This Answer Correct ? | 4 Yes | 2 No |
Post New Answer View All Answers
what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?
How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?
Can we use shunt trip coil instead of trip coil with protection relay for protection?
How many types are using in 220kv/400 kv swith yard
why transmission is only 3 phase and not 2 or 4 or poly phases
We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.
State the formula for overall efficiency of thermal power station
We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's
What is meant by reset level of the relay?
if we give 60 hz single phase supply to the transformer used in europe , than what will happen
How LT megger works ?
In a 3 phase 4-wire system. For a 3.5 core cable if all loads are single phase and balanced, what will be neutral current? will it be sum of all phase currents? Or it will be zero? And if loads are unbalanced what will be neutral current?
sir vizag steel ka junior trainee ka paper kitne number ka ayega
How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?
1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?