Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transformer are rated in kva.

Answer Posted / gaurav tripathi

in the transformer there are two losses,core loss and 'cu'
loss ,core loss depends on voltage and 'cu' loss depends on
current hence rating of transformer is on KVA not on KW

Is This Answer Correct ?    22 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to set the relay,,??

2142


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1818


What is the implications when 600 hp motor is started when the unit is running with Transformer of capacity 1500 KVA and DG set of 1000kva

2274


at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.

1725


What is electrical diversity factor in electrical installations?

1273


Load transfer in 11kv double busbar switchgear - operation.

2012


WHAT IS SITTING AMPS IN OVER-LOAD RELAY FOR 1PH OR 3PH MOTORS?IF ITS NAME PLATE GIVEN MAX AMPS 10AMPS?

1806


what is the use of vcb & isolator in substation?

2462


In siemens S7-300 PLC, what is function and function block ? What is the difference between them ? When to use function and when to use function block ?

2157


what is inverter and converter

1977


which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?

2237


How can find thermal state value in relay for calculate thermal overload.

1963


What is meant by reset level of the relay?

1251


what is harmonics? what are the factors it will depend upon

2083


where does 22kv line starts

3151