Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How many earthings are required for commissioning the
Transformer?

Answer Posted / s naidu

Hear asking required for commissing the transformer
1-body earthing- 2nos
2-Neutral earthing-2nos
3-Lighting Arester for transformer protection
LA earthing-3 nos

Is This Answer Correct ?    20 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

State and define norton’s theorem?

1205


what is the value of combined earthing in general electrical circiut?

1844


what is the effect of change in supply frequency on load angle of synchronous motor,all other parameters remaining same?

2296


Write the analogous electrical elements in force voltage analogy for the elements of mechanical translational system.

1273


What are the different types of controllers?

1030


How to Calculate Transformer Earthing Electrode Rod Size both Body and neutral Earthing ? Any Standard Formula? Please Suggted

1561


Define peak overshoot.

1217


If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?

1863


When is lag lead compensator is required?

1068


what are the dimensions for 200 kva transformer plinth (plateform),in which pcc m20 is used..

11593


I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.

1642


Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?

1677


can mini-curcuit supply MIL-tested transformer !

2079


1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?

1982


hello everybody. what does an abnormal stator winding impedance or dc resistance show? thanx

1854