What is the difference b/w OVI Solvents and Residual
Solvents in case of Gas Chromatogaphy and What is its
Detection Limit?
Answer Posted / d.sambireddy
Organic volatile impurities called OVI. Its limit is
very low.
benzene, chloroform, 1,4-dioxane, ethylene oxide, methylene
chloride and trichloroethylene
The above solvents are now included in Residuval solvents
suppose these solvents we are using (or) are not using in
process but we determine the solvents because these sovents
are toxic. its PDE is very low
RS:RESIDUAL SOLVENTS ,Theirs limits r high compared to ovi.
| Is This Answer Correct ? | 11 Yes | 7 No |
Post New Answer View All Answers
How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain
how to calibrate hplc & gc
sop of a uv visible spectrophotometer double beam elico model
Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?
We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?
which situation gc hs and gc als require to use?
what is the principle of UV Vis spectroscopy, AAS, ICP OES,ICPAES, ICP-MS and FTIR
in stress study if your api not soluble in hcl naoh h2o2 then what require to do?
in which situation ion pair agent require to use?
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
how to develop the icp ms method? Application of icp ms?
in OSD forms require to use gas chromatography?
What are modes of quantification in related substances
In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.
What is column in chromatography?