Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transformer ratinh is in KVA????/

Answer Posted / shaikh

Cu loss of transformer depends upon current I and iron loos
depends upon voltage V...So as we can say that the total
losses of the transformer depend upon VA (volt-ampere) and
independent of phase angle between V & I (i.e. pf
angle)...so transformer rating is in kVA & nt in KW...

Is This Answer Correct ?    14 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calculate fuse rating for a motor

5661


sir my exam is on 19/6/2013 under electrical branch pls send me sample aptitude questions as well as sample technical questions for jindal steel and power company

2278


What do you understand by oldham's coupling ?

1072


8. A DYNAMOMETER TYPE WATTMETER RESPONDS TO THE.......

9295


how can motor both beasrings insulation resistance can be check?

2032


What are the protection required for Transformer, motor, Line, Generator, capacitor, that all i have to refer which standard?(Like Transformer detail IS 2026)

2018


What are the conditions to be satisfied for parallel operation of dc generators?

1103


hey guys help me out.....what  are the industrial uses/functions of nozzles in industries 

1593


can i use ups power as a raw power for another ups

1983


what should be the acceptrd value of winding resistance for 2.5MVA transformer

2307


what is ramping rate of generator

2069


I would like to know that the fault curretn at base load and at 10% generation will be same? Fault level of BUS remain same with different generation?

1871


Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?

4404


1.main parts of generator? what is used A-check,B-check,C- check? 2.what is FM200 system in data centers? 3.difference between pac,ahu?

2134


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

808