Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

IN DISSOLUTION TEST S1AND S2 AND S3 CONDITIONS ALL ARE
FAILED THEN WHAT IS THE DESSICION U CAN TAKE

Answer Posted / k.g.gupta dr.reddy&

Dear RC,
IF the S1,S2,S3 stage is carried out by first officer, We should perform the analysis by second officer for conformity of OOS.
IF S1,S2,S3 stages are performed by different analysts, We have to raise the OOS and no need to perform the analysis by another officer.

Is This Answer Correct ?    2 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if content uniformity passing but dissolution varrying then what is next step?

936


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3723


in stress study if your api not soluble in hcl naoh h2o2 then what require to do?

902


How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain

2437


how you establish the LOQ?

841


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1652


if peak get problamatic then what require to do?

859


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

1003


How do we fix the sample concentaryion in hplc method development. What is the basis?

1248


Why irmoisture balance is used for corrugated box moisture testing

2449


Which parameters require to do in tech transfer?

819


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1903


what is biorelivent dissolution media?

859


What is the difference between purge septum flow and column flow in gas chromatography?

2643


Why only 1.2 million lux hours require in photostability study?

1099