Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

IN DISSOLUTION TEST S1AND S2 AND S3 CONDITIONS ALL ARE
FAILED THEN WHAT IS THE DESSICION U CAN TAKE

Answer Posted / rc

Gupta, WHEN PRODUCT IS NOT MEETING THE SPECIFICATION UPON
TESTING OF 24 UNITS ,IS IT REALLY REQUIRED TO CARRY OUT
ANALYSIS BY SECOND OFFICER?

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the purpose of octyl silane columns?

4246


WHY pKa value is more important than pH value of the mobile phase in HPLC?

1712


what is %labelled amount in content uniformity of dosage unit and its calculation?

5137


what is definition of validation? which components are followed give detail?

2292


how you fix the limits of impurities?

786


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1546


if you get peak in blank then what require to do?

909


How to establish relative response factor for hplc. Why it is required?

1150


we can use expired sample for validation and analyst qualification?

751


if tech transfer fails whay require to do?

771


In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

2175


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1909


identification is for unknown? qualification for known? reporting for LOQ?

665


WHAT IS THE USE OF STARTER ?????????

2356


UV and PDA detector, which have less signal to noise ratio?

1082