Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

IN DISSOLUTION TEST S1AND S2 AND S3 CONDITIONS ALL ARE
FAILED THEN WHAT IS THE DESSICION U CAN TAKE

Answer Posted / senthilkumar

Product further investigate and if need re sampling once
again will do it through oos and do re analysis

Is This Answer Correct ?    7 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In rs method development when we are going area normalization method to dilute standard method?

1520


Which parameters require to do in tech transfer?

754


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1627


What is the calibration of uv process and preparation

1997


Why use only methanol,used determinationof moisture content not use other solvents

1404


what is definition of validation? which components are followed give detail?

2370


Why irmoisture balance is used for corrugated box moisture testing

2404


how you determine moist.of NaOH sol or NaOH flacks

2222


what are the standard methods for HPLC?

2786


How to establish relative response factor for hplc. Why it is required?

1224


What is dose dumping? why require to do?

948


what is biorelivent dissolution media?

807


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3178


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1850