Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between IR & FTIR ? how we calibarte
both ? I want to know the procedure.

Answer Posted / bhalchandra farde anuh pharma

In FTIR providing interferometer techniqe ,it is
mathamatical operation by in which possible scanning done
40 times in one minutes and give better resolution . It is
calibrated by using Polystyrene film ( MIR flim ) 0.38 mm
for wave number , Resolution & noise test etc.

Is This Answer Correct ?    51 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

1984


in hplc chromatogram started from left to right and in uv spectrum started from left to right

887


what is the purge flow & how to calculate

2557


what is the importance of peak purity in HPLC and how we can calculate through manul(not software)?

4417


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7471


Identify problem faced when mass spectroscopy is used with HPLC system ?

1797


Is it nessesary all multimedia dissolution require descriminatory?

738


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

764


In rs method development when we are going area normalization method to dilute standard method?

1473


As per ICH related substances stability trend limit from initial to shelf life

3179


how require to interprit the method precision data of hptlc?

758


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1834


how much mass should be there in volumetric flask while in preparation of sample for assay? 

2509


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

842


How we can identify process related and degradation impurity in single method with short period?

757