Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between IR & FTIR ? how we calibarte
both ? I want to know the procedure.

Answer Posted / bhalchandra farde anuh pharma

In FTIR providing interferometer techniqe ,it is
mathamatical operation by in which possible scanning done
40 times in one minutes and give better resolution . It is
calibrated by using Polystyrene film ( MIR flim ) 0.38 mm
for wave number , Resolution & noise test etc.

Is This Answer Correct ?    51 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What should be the level/ Percentage of Arsenic in Arsenic free zinc.

2233


how you start the solubility study?

824


Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .

911


Loss of linearity in tkn analysis, possible reasons?

1315


AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2050


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3539


in OSD forms require to use gas chromatography?

834


why require to do water content for drug product?

826


how to get accurate result for Residue on evaporation in purified water

1645


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1971


What is the formula to determine the concentration of M of a solution given the % transmittance? Use %T = 43.7 as an example.

2682


if you given one product then which tests you will perform?

704


How require to perform linearity as per ANVISA? What are the acceptance criteria?

1334


how can I make the copper get white bye any salt or acit?

2207


if you have given a blank water how you analyse by general analytical techniques?

2028