in a electronic controller why we are using 250 ohm
resistance in input signal?is i/p is necessary in control
valve when we are using electronic controller give details?
Answer Posted / rohit
A electronics controller needs 4-20mA current and we have
230v or more voltage in industry so to maintain flow of
current 250 ohm resistance is vital.
I=V/R
| Is This Answer Correct ? | 2 Yes | 16 No |
Post New Answer View All Answers
Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection
installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.
HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.
can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.
why we are using drum level control valve air to close?
what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.
What is Droop? What is Step/Gradient Limiter in Turbine Governor control?
hello can yoy pls send me previous papers of jindalpower and steel ltd.....'m from instrumentation..... mani1048@gmail.com
what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .
what is the calibration procedure for transweigh make weigh feeder?
How we calculate orifice plat size???
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
How to calibrate Field bus transmitter? procedure ?
How is automatic reference junction compensation carried out in temperature recorders?