Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between M.C and LOD

Answer Posted / amit patel

M.C =moisture content= the molecular water stored in the
molecule/it gives the exact water centent.(generally tested
by the KF titrator)

whereas

LOD=Loss on drying= unbound water + organic volatile
impurities.(in vacuum oven)

Is This Answer Correct ?    34 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is mean by nitrosamine impurities?

1069


Which is the highly polar and highly non polar column in HPLC?

2309


what is the origin to prepare standard operating procedure

2338


what is mean by covalidation

786


UV and PDA detector, which have less signal to noise ratio?

1137


how can I make the copper get white bye any salt or acit?

2213


What is control room temperature and which guide line says?

1647


what is the acceptance criteria for enteric coated tablets in 0.1n hcl validation in each parameter?

894


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


what is mean by ambient temperature?

921


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2874


How will u perform degradation study in detectors other thann PDA in HPLC Methodology

2549


EXPLAIN THE CALCULATION PART OF AN KF TITRATOR CALIBRATION WITH SUITABLE EXAMPLE

2644


What is the use of tlc and hplc? And when and where use?

1168


What is importance of pH in the Heavy metal test and How it effect on the test results?

2287