Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the rating of your substation and what are the
different types of substations?

Answer Posted / pillay

It is a 5 MVA 11KV/433 VOLT INDOOR SUBSTATION.
A) Indoor substation
B) Outdoor substation
C) Compact substation

Is This Answer Correct ?    11 Yes 17 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How does a battary stores charge in it? please explain in simple manner and in detail.thanks

1940


What is the importance of counter based plan & how is it scheduled?

1980


How relay works, reverse relay, master relay, os relay, earth fault relay and what is its setting point

1736


What is the actual meaning of thermal power efficiency ?

2082


How to Make relay co ordination chart for a Electrical power distribution of a plant

3788


Explain the laying procedure and laying depth of submarine/subsea power cable for 220/400KV system? Also available cable diameter?

2071


what is x'mer ,isolation x'mer & yltra-isolation x'mer?????

2408


How to calculate the phase to phase clearness of HT /// LT bus bar?????

2039


HI....HOW CAN BE MESARED THE VALVE OF NEUTRAL GROUND RESISTOR WHIC IS LOCATED AT SWICHGEAR ON GENERATOR SIDE....

2040


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1737


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1894


what is the formula to calculate voltage drop/loss on 66KV Transmission Line?

3652


what's the exact magnitude of current, flows through Neutral?

1923


What is Long rod insulator and it's applications..? merits over the disc insulator ..?

1869


Where servomechanism is used?

1049